Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Spectrophotometers and Photometers>>Basic Photometers>>เครื่องโฟโตมิเตอร์-ไนเตรท (Nitrate Photometer 0.0- 30.0 mg/L)
  • header_20100925213226.jpg

    เครื่องโฟโตมิเตอร์-ไนเตรท (Nitrate Photometer 0.0- 30.0 mg/L)

    HI 93728

    Nitrate Photometer with 555 nm LED

              Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.

    A maximum level of 45 mg/L is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L, while in the USA the EPA has established a guideline for the maximum level of nitrate nitrogen of 10 mg/L (NO-³-N), which corresponds to 45.0 mg/L of nitrates.

    The HANNA® solutions are HI 93728 and HI 93828, hand held meters suited for field measurement. Reading procedures have been made as simple as possible to allow everyone to perform accurate nitrate measurements.

    The kit provides you with all you need for field measurement: photometer, reagents and apparatus perfectly fitted in a rugged carrying case

    • HI 93728 reads nitrogen nitrate from 0 to 30 mg/L (NO-³-N); multiply the readout by a factor of 4.43 and you can read up to 133 mg/L of nitrate (NO-³).
    • HI 93828 reads nitrate directly in mg/L of NO-³, from 0 to 100 mg/L.

    With a normal 9V battery you will be able to get more than 300 measurements. The auto shut-off feature (after 10 minutes of non-use) guarantees a long battery life.

    Order Information:
    HI 93728 is supplied with 2 cuvets, battery and instructions.
    **Add “C” to end of Product Code for the kit which includes a hard carrying case and reagents.

    Specifications

    Range   0.0 to 30.0 mg/L (NO³-N)
    Resolution   0.1 mg/L
    Accuracy   ±0.5 mg/L ±10% of reading
    Light Source   LED 555 nm
    Light Life   Life of the instrument
    Light Detection   Silicon Photocell
    Battery Type / Life   1 x 9V / approx. 40 hours of continuous use;
    auto-off after 10 minutes of non use
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
    Weight   290 g (10 oz.)
    Method   Adaptation of cadmium reaction method. The reaction between
    nitrate-nitrogen and the reagent causes an amber tint in the sample

    Solutions

    HI 93703-50 Solution for Cleaning Cuvets

    Accessories

    HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
    HI 731325 Cuvet Cap Turbidity Meters & HI 937xx Series Meters
    HI 710009 Shockproof Boot, Blue
    HI 710010 Shockproof Boot, Orange
    HI 731318 Tissue for Wiping Cuvets
    Reagents & Standards
    HI 93728-01 Nitrate, Cadmium Reduction Method (100 Tests)
    HI 93728-03 Nitrate, Cadmium Reduction Method (300 Tests)

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<