Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Spectrophotometers and Photometers>>Advanced single Parameter Photometers>>เครื่องโฟโตมิเตอร์-แอมโมเนีย (Ammonia Photometer 0.00- 9.99 mg/L)
  • header_20101001232018.jpg

    เครื่องโฟโตมิเตอร์-แอมโมเนีย (Ammonia Photometer 0.00- 9.99 mg/L)

    HI 96715

    Ammonia, Medium Range Photometer with 466 nm filter and Cal Check

              Ammonia is naturally present in water, as it is a product of the protein microbiological decay of animals and plants. High ammonia concentration in surface waters indicate domestic pollution. Moreover, ammonia and its compounds are used in fertilizers. HI 96715 is an auto-diagnostic portable photometer for accurately measuring nitrite nitrogen. The advanced optical system employs a specialized LED and a narrow band interference filter, assuring accurate readings between 0.00 to 9.99 mg/L (as NH3 -N). This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time.

     Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration.

    Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. Reagents are in powdered form and are supplied in packets. The amount of reagent is precisely dosed to ensure maximum repeatability. HI 96715 utilizes an adaptation of ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.

    Order Information:

    HI 96715 is supplied with (2) sample cuvets with caps, 9V battery and instruction manual.

    HI 96715C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, tissue for wiping cuvets, 9V battery and instruction manual in a hard carrying case.

    Specifications

    Parameter   Ammonia, Medium Range
    Range   0.00 to 9.99 mg/L (as NH³-N)
    Accuracy   ±0.12 mg/L @ 6.00 mg/L
    Filter   Narrow band @ 466 nm
    Method   Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.
    Light Source   Tungsten lamp; LED
    Environment   0 to 50°C (32 to 122°F); Max 95% RH non-condensing
    Battery Type / Life   (1) 9V/approx. 200 hours continuous use
    Auto Shut-off   After 10 min. of non-use in measurement mode
    Dimensions   192 x 102 x 67 mm (7.6 x 4 x 2.6″)
    Weight   290 g (10 oz.)

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<