    HI 736

    Phosphorus Ultra Low Range

    Easier to use and more accurate than chemical test kits

    Adaptation of Standard Method Ascorbic Acid Accuracy ±5% of reading ±5% ppb 1 ppb resolution (200 points) Large, easy to read digits Auto shut-off.

    Dedicated to a single parameter

    Designed to work with HANNA’s powder reagents Uses 10 mL glass cuvettes.

    Small Size, Big Convenience
    Weighing a mere 64 g (2.25 oz.), the Checker®HC easily fits into the palm of your hand or pocket Use for quick and accurate on the spot analysis Single button operation: Zero and Measure Operated by a single AAA battery.

    ACCURATE AND AFFORDABLE PHOSPHOROUS MEASUREMENT

    Phosphorous (as phosphate) can be introduced to aquaria through feed, decaying plant and animal waste, and even tap water, so it can quickly become so abundant that it becomes a nuisance. Phosphate is a driving factor in excess algae growth, so it is important to keep levels as close to zero as possible. The HANNA HI 736 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 736 Checker®HC is accurate and affordable.

    This Checker®HC features an accuracy of ±5% of reading and uses an adaptation of Standard Method Ascorbic Acid. The contoured style of this Checker®HC fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off. The HI 736 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagent. Last, Place the vial into the HI 736 Checker®HC, press the button and read the results. It’s that easy.

    Order Information:
    HI 736 Checker HC is supplied with (2) sample cuvettes with caps, (6) powder reagents for phosphorus, (1) 1.5V AAA battery and instructions.

    Specifications

    Range   0 to 200 ppb
    Resolution   1 ppb
    Accuracy   ±5% of reading ±5% ppb @ 25ºC
    Light Source   LED @ 525 nm
    Light Detector   Silicon photocell
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Battery Type   (1) 1.5V AAA
    Auto-off   After 3 minutes of non-use
    Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
    Weight   64 g (2.25 oz.)
    Method   Adaptation of Standard Method Ascorbic Acid.

    Accessories

    HI 731318 Tissue for Wiping Cuvets
    HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
    HI 731225 Caps for cuvet
    HI 93703-50 Solution for Cleaning Cuvets
    Reagents & Standards
    HI 736-25 Reagents for 25 tests (phosphorus)
    HI 736-11 Calibration standard kit

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<