    HI 93740

    Nickel Photometer with 555 nm LED

              Nickel is commonly utilized by the electroplating industry in processes utilizing stainless steel, cobalt or nickel alloys.

    Even though nickel is regarded as non-toxic to human, concentrations found in wastewater exceeding 0.5 mg/L can cause damage to certain plants and aquatic life.

    Nickel is also used in batteries, fuel cells and hydrogenation of vegetable oils in the food industry.

    HANNA® offers two different meters to measure nickel:HI 93726 for high range (0.00 to 7.00 g/L) and HI 93740 for low range (0.000 to 1.000 mg/L), both with outstanding accuracy given by internal microprocessor calibration.

    Both the high and low range nickel meters have been designed to be comfortably handled.

    They weigh less than 300g (11 oz.) and their long battery life make them ideal for field measurements.

    Order Information:
    HI 93740 is supplied with 2 cuvets, battery and instructions.

    Specifications

    Range   0.000 to 1.000 mg/L
    Resolution   0.001 mg/L
    Accuracy   ±0.010 mg/L ±7% of reading
    Light Source   LED 555 nm
    Light Life   Life of the instrument
    Light Detection   Silicon Photocell
    Battery Type / Life   1 x 9V / approx. 40 hours of continuous use;
    auto-off after 10 minutes of non use
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
    Weight   290 g (10 oz.)
    Method   Adaptation of the PAN method;
    The reaction between nickel and the reagent
    causes an orange tint in the sample

    Solutions

    HI 93703-50 Solution for Cleaning Cuvets

    Accessories

    HI 731325 Cuvet Cap Turbidity Meters & HI 937xx Series Meters
    HI 710009 Shockproof Boot, Blue
    HI 710010 Shockproof Boot, Orange
    HI 731318 Tissue for Wiping Cuvets
    HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
    Reagents & Standards
    HI 93726-01 Nickel HR, Photometric Method (100 Tests)
    HI 93726-03 Nickel HR, Photometric Method (300 Tests)
    HI 93740-01 Nickel LR, PAN Method (100 Tests)
    HI 93740-03 Nickel LR, PAN Method (300 Tests)

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<