    เครื่องโฟโตมิเตอร์-ความกระด้างทั้งหมด (Total Hardness Photometer 0- 750 mg/L)

    HI 93735

    Full Range of Total Hardness in ppm, °fH, °dH and °eH

              Total hardness, that is the presence of magnesium and calcium, is due mainly to the run-off water dissolving these salts as it flows or filters through different strata.

    Hardness can also cause scaling of pipes in cooling and heating systems. Reverse osmosis and demineralization also increase hardness levels.

    The HANNA® hardness meter, HI 93735, measures total hardness in three different scales: 0 to 250, 200 to 500 and 400 to 750 ppm, covering an extensive range of applications.

    With HI 93735 hardness can be measured in ppm (mg/L) as well as in French (°fH), German (°dH) and English hardness (°eH).

    The reading is expressed directly in ppm and it is not necessary to use conversion tables and diagrams for interpretation.

    Order Information:
    HI 93735 is supplied with 2 cuvets, battery and instructions.

    Specifications

    Range ppm 0 to 250 mg/L; 200 to 500 mg/L; 400 to 750 mg/L
    Range ºf 0 to 25; 20 to 50; 40 to 75
    Range ºD 0.0 to 13.9; 11.1 to 27.8; 22.2 to 41.7
    Range ºE 0.0 to 17.5; 14.0 to 35.0; 28.0 to 52.5
    Resolution   1 mg/L (0 to 100 mg/L); 5 mg/L (100 to 750 mg/L)
    Accuracy   ±5 mg/L or ±4% of reading (0 to 250 mg/L);
    ±7 mg/L or ±3% (200 to 500 mg/L); ±10 mg/L or ±2% (400 to 750 mg/L)
    Light Source   LED 470 nm
    Light Life   Life of the instrument
    Light Detection   Silicon Photocell
    Battery Type / Life   1 x 9V / approx. 40 hours of continuous use;
    auto-off after 10 minutes of non use
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
    Weight   290 g (10 oz.)
    Method   Adaptation of the EPA 130.1 method. The reaction between
    Ca or Mg and the reagents causes a red-violet tint in the sample.

    Solutions

    HI 93703-50 Solution for Cleaning Cuvets

    Accessories

    HI 731325 Cuvet Cap Turbidity Meters & HI 937xx Series Meters
    HI 710009 Shockproof Boot, Blue
    HI 710010 Shockproof Boot, Orange
    HI 731318 Tissue for Wiping Cuvets
    HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
    Reagents & Standards
    HI 93735-00 Hardness, Total, Range: 0 to 250 mg/L      Colorimetric Method (100 Tests)
    HI 93735-01 Hardness, Total, Range: 200 to 500 mg/L  Colorimetric Method (100 Tests)
    HI 93735-02 Hardness, Total, Range: 400 to 750 mg/L  Colorimetric Method (100 Tests)
    HI 93735-0 Hardness, Total, Range: 0 to 750 mg/L     Colorimetric Method (100 Tests)

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<