Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Spectrophotometers and Photometers>>Cal Check™ Photometers>>เครื่องโฟโตมิเตอร์-คลอไรด์ (CHLORIDE Photometer 0.0- 20.0 mg/L)
  • header_20100926223045.jpg

    เครื่องโฟโตมิเตอร์-คลอไรด์ (CHLORIDE Photometer 0.0- 20.0 mg/L)

    HI 96753

    CHLORIDE PHOTOMETER

              Chloride ions are one of the major inorganic anions in water and wastewater. Although high concentrations of chloride in water are not known to be toxic to humans, its regulation is mainly due to adverse effects on taste. It is essential to monitor chloride concentrations in boiler systems to prevent metal parts from being damaged. In high levels, chloride can corrode stainless steel. The level of chloride concentrations in boiler and cooling towers varies from small quantities to very high levels. Furthermore high levels of chloride can be toxic to plant life. Chloride is a common non-toxic material present in small amounts in drinking water and produces a detectable salty taste at the aesthetic objective level of 250 mg/L (limit referred to the EPA Maximum Contaminant Level [MCL]). Measured levels are normally under 20 mg/L (ppm).

    Order Information:
    HI 96753 is supplied with (2) sample cuvettes with caps, 9V battery and instructions. CAL CHECK™ standards and reagents sold separately.

    Specifications

    Range   0.0 to 20.0 mg/L (ppm)
    Resolution   0.1 mg/L (ppm)
    Precision   ±0.5 mg/L ±6% of reading
    Light Source   LED
    Light Detector   Silicon photocell with narrow band interference filter @ 466 nm
    Power Supply   (1) 9V battery
    Auto-off   After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   192 x 102 x 67 mm (7.6 x 4 x 2.6”)
    Weight   290 g (10 oz.)
    Method   Adaptation of the mercury(II) thiocyanate method.
    Reagents & Standards
    HI 96753-11 CAL CHECK™ standard cuvettes
    HI 93753-01 Chloride, Mercury (II) Thiocyanate Method (100 Tests)
    HI 93753-03 Chloride, Mercury (II) Thiocyanate Method (300 Tests)

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     