    เครื่องโฟโตมิเตอร์-คลอรีนอิสระ (Free Chlorine Photometer 0.000- 0.500 mg/L)

    HI 96762

    Free Chlorine, for Drinking Water Applications Photometer with 525 nm filter and Cal Check

              Chlorine, the most ubiquitous disinfectant, is used in many treatment applications; from potable water, wastewater, to food industry and swimming pools. HI 96762 is an auto-diagnostic portable photometer for accurately measuring free chlorine. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings between 0.000 to 0.5000 mg/L. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time.

    Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration.

    Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. Reagents are in powdered form and are supplied in packets. The amount of reagent is precisely dosed to ensure maximum repeatability. HI 96762 utilizes an adaptation of Standard Methods, 20th Edition, 4500-Cl G. The reaction between chlorine and the DPD reagent causes a pink tint in the sample.

    Order Information:
    HI 96762 supplied with (2) sample cuvettes with caps, 9V battery and instructions. CAL CHECK™ standards and reagents sold separately

    Specifications

    Range   0.000 to 0.500 mg/L (ppm)
    Resolution   0.001 mg/L (ppm)
    Precision   ±0.004 mg/L to 0.200 mg/L (ppm)
    Light Source   Tungsten lamp
    Light Detector   Silicon photocell with narrow band interference filter @ 525nm
    Power Supply   (1) 9V battery
    Auto-off   After 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder.
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   192 x 102 x 67 mm (7.6 x 4 x 2.6”)
    Weight   290 g (10 oz.)
    Method   Adaptation of the Standard Method 4500-Cl G.
    Reagents & Standards
    HI 95762-01 Chlorine, Free, ULR, DPD Method (100 Tests)
    HI 95762-03 Chlorine, Free, ULR, DPD Method (300 Tests)
    HI 95762-11 Cal Check® Standard cuvet for HI 95762

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<