Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Meters and Measurements>>Dissolved Oxygen Handheld Testers>>เครื่องมือวัดค่าออกซิเจนละลาย, อุณหภูมิ แบบมือถือ (Cyber Scan DO 600)
  • header_20100402181323.jpg

    เครื่องมือวัดค่าออกซิเจนละลาย, อุณหภูมิ แบบมือถือ (Cyber Scan DO 600)

    Product Features

    :: Measures oxygen concentration up to 90.00mg/L and Saturation up to 600.0% – one of the widest measurement range in the DO handheld market today!
       
    :: Mega-storage space saves up to 500 data sets stamped with time and date – Perfect for GLP-compliant researches
       
    :: Salinity, temperature and pressure compensation – accurate even under varying conditions
       
    :: Comprehensive one-glance-tells-all screen with intelligent screen prompts.
       
    ::
    Cal-due alarm on real-time clock ensures periodic calibration updates.
       
    :: IP67 waterproof design for applications in harsh environments
       
    :: Auto-logging function automatically records up to 500 data sets stamped with date and time–Great for GLP-compliant researches
       
    :: LED-RS232* and IrDA Wireless Communication for direct Meter-to-PC data transfer.
       
    :: Convenient 2-point calibration with step-by-step calibration guide.
       
    :: Galvanic, so you don’t have to wait for meter to
    warm up.

    Applications

    Routine Testing: For quick, accurate dissolved oxygen checks in laboratories, field and schools. Useful in aquaculture and aquariums.

    Industrial: Biological Wastewater Treatment; Fermentation

    Water Quality Testing: Environmental monitoring

    Specifications

    Dissolved Oxygen
    Range: 0.00 to 90.00 mg/L or ppm
    Resolution: 0.01 mg/L or ppm
    Accuracy: ±0.2 mg/L
    % Saturation
    Range: 0.0 to 600.0%
    Resolution: 0.1%
    Accuracy: ±2 %
    Temperature
    Range: 0.0 to 50.0 °C (32 to 122 °F)
    Resolution: 0.1 °C (0.1 °F)
    Accuracy: ±0.3 °C (±0.5 °F)
    Compensation: ATC / MTC (0.0 to 50 °C)
    Salinity Correction
    Range: 0.0 to 50.0 ppt
    Resolution: 0.1 ppt
    Method: Automatic correction after manual input
    Pressure Correction
    Range: 450 to 825mmHg (59.9 to 109.9 kPa)
    Resolution: 0.1 mmHg (0.1 kPa)
    Method: Automatic correction with inbuilt sensor
    Calibration
    2 Point (0%, 100%)
    Operating Range
    0.0 to 50.0 °C (32 to 122 °F)
    Probe Type
    Galvanic
    Date/Time Stamping
    Yes
    Memory
    500 data sets (GLP-compliant format)
    Special Functions
    Auto-Hold; Auto Power-Off after 2 – 30 minutes (user-preset); Stability Indicator; Self-diagnostics messages 
    Power
    4 x 1.5 ‘AA’ batteries (>400 hours) or 9V DC adapter, 500 mA

     

    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<