    อุปกรณ์วัด Turbidity (Turbidity Benchtop Meter, ISO)

    HI 88713

    Turbidity Benchtop Meter, ISO

     

    • Graphic display, backlit LCD
    • Two, three, four or five point calibration
    • GLP features
    • Log up to 200 records
    • Contextual help and tutorial mode
    • USB PC connectivity

    The HI 88713 turbidity bench meter meets and exceeds the requirements of the
    ISO 7027 standard.

    HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.

    Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

    A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.

    The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.

    The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.

    Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

    Order Information:
    HI 88713-01 (115V) and HI 88713-02 (230V) are supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.

     

     Specifications

    Range FNU Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
      FAU Mode 10.0 to 99.9; 100 to 4000 FAU
      NTU Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
      NTU Non-Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
    Resolution FNU Mode 0.01; 0.1; 1 FNU
      FAU Mode 0.1; 1 FAU
      NTU Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
      NTU Non-Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
    Accuracy @25°C FNU Mode ±2% of reading plus stray light
      FAU Mode ±10% of reading
      NTU Ratio Mode ±2% of reading plus stray light / ±5% of reading above 1000 NTU
      NTU Non-Ratio Mode ±2% of reading plus stray light
    Range Selection   automatic
    Repeatability   ±1% of reading or stray light, whichever is greater
    Stray Light   < 0.1 NTU (0.05 EBC)
    Light Detector   silicon photocell
    Light Source   IR LED
    Method   ISO 7027 Method
    Measuring Mode   normal, average, continuous.
    Turbidity Standards   <0.1, 15, 100, 750 FNU and 2000 NTU
    Calibration   two, three, four or five-point calibration
    Log Memory   200 records
    PC Connectivity   USB
    Environment   0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
    Power Supply   12 Vdc power input
    Dimensions / Weight   230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<