    อุปกรณ์วัด Turbidity (Portable Turbidity Meter and Bentonite Monitoring)

    HI 83749

    Portable Turbidity Meter and Bentonite Monitoring

     

    • GLP Features
    • Fast Tracker™ with iButton™ tags    
    • Continuous measurement mode; Verifies the settling rate of suspended matter.
    • Signal Average (AVG) mode; Accumulates multiple readings giving a final average value.
    • Backlit LCD
    • USB

    Wines with low phenol contents, such as rosé, light reds and whites should be checked for protein stability before bottling. HANNA is offers a quick test to verify the risk of future protein haze formation. If protein instability is detected, a subsequent test can help define the right amount of bentonite to be added for improving protein stability. It is important not to overdose bentonite to avoid stripping wine flavor, body, and significant loss of color, especially in young red wines. Moreover, adding only the necessary amount of bentonite to obtain the desired protein stability also saves costs.

    The HI 83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. In the USEPA measurement mode the instrument rounds the readings to meet USEPA reporting requirements.

    Order Information:
    HI 83749-01
     (115V), HI 83749-02 (230V) and HI 83749-03 (AUS plug) are supplied with sample cuvettes and caps (6), calibration cuvettes (HI 83749-11) (4), bentocheck reagent (HI 83749-0) and silicone oil (HI 93703-58), 1000 µL automatic pipette with two tips and instructions sheet, 25 mL glass vials with caps (4), 1 mL syringe with two tips, funnel, filter paper (25), cuvette cleaning cloth, 12 VDC adapter, batteries, instructions and rugged carrying case.

     

     Specifications

    Range   0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1200 NTU automatic range selection
    Resolution   0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1200 NTU
    Accuracy @25°C   ±2% of reading plus 0.05 NTU
    Repeatability   ±1% of reading plus 0.05 NTU
    Stray Light   < 0.05 NTU
    Light Source   tungsten filament lamp
    Light Detector   silicon photocell
    Method   Ratio Nephelometric
    Calibration   two, three or four points
    Log Memory   200 records
    PC Connectivity   RS232 or USB 1.1
    Environment   0 to 50°C; max 95% RH non-condensing
    Power Supply   1.5V AA batteries (4) / 12 VDC adapter
    Auto-off   after 15 minutes of non-use
    Dimensions / Weight   224 x 87 x 77 mm (8.7 x 3.3 x 3.1″) / 512 g (17.6 oz.)
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<