Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Turbidity>>Turbidity (Portable Turbidity Meter)>>อุปกรณ์วัด Turbidity (measures turbidity and chlorine free / total)
  • header_20130408125929.jpg

    อุปกรณ์วัด Turbidity (measures turbidity and chlorine free / total)

    HI 93414
    measures turbidity and chlorine free / total

    The HI 93414 turbidimeter using a tungsten light source meets the EPA (Environmental Protection Agency) and an advanced optical system, thanks to which we can make measurements of turbidity and chlorine free / total very accurate and reliable. The scale for the measurement of turbidity extends up to 1000 NTU, while the analysis of free or total chlorine may be carried out on a scale from 0.00 to 5.00 mg / l (ppm). Even the metering modes comply with the EPA rules: Depending on the measured sample and needed accuracy, users can opt for a normal measurement, continuous or for the AVG mode, which performs many reads and returns an average value.
    This tool is equipped with the TIS – Tag Identification System, developed by HANNA, which allows users to record all measures indicating the date and place where they were made. The stored data can then be transferred to a PC via USB or RS 232.
    The reliability of the instrument is guaranteed by the system Cal Check ® and the chlorine standard NIST ready to use. For turbidity calibration standards are available in two, three or four points, pre-defined or user-settable. Frequent calibration is not necessary as the system compensates for variations in the intensity of the light source.
    feature GLP (Good Laboratory Practice) allows the traceability of calibration data, including date, time, and the last calibration points.

     

     Specifications

     Stray Light    <0.02 NTU
    Sensor / s    Turbidity: two silicon photocells;
    Chlorine: Silicon photocell with narrow band interference filter @ 525 nm
    Measurement mode    normal, continuous, signal averaging
    Standard    Turbidity: <0.1, 15, 100 and 750 NTU
    Chlorine: 1 mg / L free chlorine, 1 mg / l total chlorine
    Calibration    Turbidity: procedures 2, 3 or 4 points
    Chlorine: procedure to a point
    Light Source    tungsten lamp
    Time source    more than 100,000 readings
    Display    60 x 90 mm LCD with backlight
    Retention    200 samples
    Repeatability    ± 1% of reading or ± 0.02 NTU
    Interfaces    USB and RS232
    Terms of use    up to 50 ° C, max 95% RH non-condensing
    Supply    4 x 1.5V AA alkaline or adapter, auto power off after 15 minutes of inactivity
    Dimensions and weight    224 x 87 x 77 mm, 512 g

  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<