อุปกรณ์วัด Turbidity (Complete Tool for Water Analysis Turbidity, Cl2, pH, Br, Fe, I and CYS)
HI 93102
Complete Tool for Water Analysis
Turbidity, Cl2, pH, Br, Fe, I and CYS
- USEPA Compliance. In the turbidimetric mode, the HI 93102 uses the nephelometric principle according to USEPA’s 180.1 method and the Standard Method 2130B.
- Custom Calibration Points. Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU.
- Logging Capability. The HI 93102 makes it possible to log and retrieve up to 25 different samples.
The most important parameters needed for water analysis, especially in drinking water, can be measured with HANNA’s HI 93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYS). Achieve laboratory results in the field quickly and easily.
Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Miniaturization of the electronics has made it possible to offer unsurpassed accuracy and quality in a portable unit weighing just one pound!
Order Information:
HI 93102 is supplied with measurement cuvette cap, batteries and instruction manual.
Specifications
Range | Turbidity | 0.00 to 9.99 NTU / 0.00 to 50.0 NTU |
Bromine | 0.00 to 8.00 mg/L (ppm) | |
Free Cl2 | 0.00 to 2.50 mg/L (ppm) | |
Total Cl2 | 0.00 to 3.50 mg/L (ppm) | |
CYS | 0 to 80 mg/L (ppm) | |
Iodine | 0.0 to 12.5 mg/L (ppm) | |
Iron LR | 0.00 to 1.00 mg/L (ppm) | |
pH | 6.5 to 8.5 pH | |
Resolution | Turbidity | 0.01 and 0.1 NTU |
Bromine | 0.01 mg/L (ppm) | |
Free and Total Cl2 |
0.01 mg/L (ppm) | |
CYS | 1 mg/L (ppm) | |
Iodine | 0.1 mg/L (ppm) | |
Iron LR | 0.01 mg/L (ppm) | |
pH | 0.1 pH | |
Accuracy @25°C | Turbidity | ±0.5 NTU or ±5% of reading (whichever is greater) |
Bromine | ±0.08 mg/L (ppm) ±3% of reading | |
Free and Total Cl2 |
±0.03 mg/L (ppm) ±3% of reading | |
CYS | ±1 mg/L (ppm) ±15% of reading | |
Iodine | ±0.1 mg/L (ppm) ±5% of reading | |
pH | ±0.1 pH | |
Calibration | two points; selectable between 0.00 – 50.0 FTU (0.00 and 20.0 FTU recommended) | |
Light Source | pure green LED | |
Light Detector | silicon photocell | |
Battery Type / Life | 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% (non condensing) | |
Dimensions / Weight | 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) |
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit
E-mail : info@highents.com