Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Turbidity>>Turbidity (Portable Turbidity Meter)>>อุปกรณ์วัด Turbidity (Complete Tool for Water Analysis Turbidity, Cl2, pH, Br, Fe, I and CYS)
  • header_20130408123415.jpg

    อุปกรณ์วัด Turbidity (Complete Tool for Water Analysis Turbidity, Cl2, pH, Br, Fe, I and CYS)

    HI 93102

    Complete Tool for Water Analysis
    Turbidity, Cl2, pH, Br, Fe, I and CYS

    • USEPA Compliance. In the turbidimetric mode, the HI 93102 uses the nephelometric principle according to USEPA’s 180.1 method and the Standard Method 2130B.
    • Custom Calibration Points. Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU.
    • Logging Capability. The HI 93102 makes it possible to log and retrieve up to 25 different samples.

     

    The most important parameters needed for water analysis, especially in drinking water, can be measured with HANNA’s HI 93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYS). Achieve laboratory results in the field quickly and easily.

    Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Miniaturization of the electronics has made it possible to offer unsurpassed accuracy and quality in a portable unit weighing just one pound!

    Order Information:
    HI 93102 is supplied with measurement cuvette cap, batteries and instruction manual.

     

     Specifications

     

    Range Turbidity 0.00 to 9.99 NTU / 0.00 to 50.0 NTU
      Bromine 0.00 to 8.00 mg/L (ppm)
      Free Cl2 0.00 to 2.50 mg/L (ppm)
      Total Cl2 0.00 to 3.50 mg/L (ppm)
      CYS 0 to 80 mg/L (ppm)
      Iodine 0.0 to 12.5 mg/L (ppm)
      Iron LR 0.00 to 1.00 mg/L (ppm)
      pH 6.5 to 8.5 pH
    Resolution Turbidity 0.01 and 0.1 NTU
      Bromine 0.01 mg/L (ppm)
      Free and
    Total Cl2
    0.01 mg/L (ppm)
      CYS 1 mg/L (ppm)
      Iodine 0.1 mg/L (ppm)
      Iron LR 0.01 mg/L (ppm)
      pH 0.1 pH
    Accuracy @25°C Turbidity ±0.5 NTU or ±5% of reading (whichever is greater)
      Bromine ±0.08 mg/L (ppm) ±3% of reading
      Free and
    Total Cl2
    ±0.03 mg/L (ppm) ±3% of reading
      CYS ±1 mg/L (ppm) ±15% of reading
      Iodine ±0.1 mg/L (ppm) ±5% of reading
      pH ±0.1 pH
    Calibration   two points; selectable between 0.00 – 50.0 FTU (0.00 and 20.0 FTU recommended)
    Light Source   pure green LED
    Light Detector   silicon photocell
    Battery Type / Life   1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes
    Environment   0 to 50°C (32 to 122°F); RH max 95% (non condensing)
    Dimensions / Weight   220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.)
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<