อุปกรณ์วัด pH (pH/ORP/Temperature Meter with Built-in Printer)
HI 122
pH/ORP/Temperature Meter with Built-in Printer
HI 122 is a benchtop instrument featuring a built-in printer, Calibration Check™, electrode response time and condition monitoring, and enhanced diagnostic messages during calibration.
This meter uses HANNA’s “P” series of electrodes. For more accuracy, these meters also check if the measurement is outside the calibration range and warns the user in case measurements are too far outside the calibration points. Calibration can be performed in up to five points using the standard seven buffers that are automatically recognized, or by using two custom buffer values. The buffer(s) used during calibration are displayed on the LCD even when in measurement mode.
Users can log on demand up to 50 samples (50 samples per channel for dual channel model). These meters have automatic data logging of up to 1000 points (1000 points per channel for dual channel model) with flexible starting and stopping criteria.
This instrument provides GLP capabilities that allows for the storage and retrieval of all data regarding pH, rel mV, EC and NaCl calibration as well as data regarding the maintenance and status of the electrode.
Printing
The built-in impact printer incorporated into the HI 122 uses regular paper that does not fade with time. A complete set of information based on the measured, set or recorded data can be printed on demand (for current reading in measurement mode, GLP and SETUP modes) or automatically (for autolog and log on demand modes). These models also allow users to print detailed information in four languages for specific help screens and instrument set-up.
Specifications
Range pH -2.00 to 16.00 pH; -2.000 to 16.000 pH
ORP ±999.9 mV; ±2000 mV
Temperature -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution pH 0.01 pH / 0.001 pH
ORP 0.1 mV / 1 mV
Temperature 0.1°C (0.1ºF)
Accuracy pH ±0.01 pH / ±0.002 pH
ORP ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV)
Temperature ±0.4°C (±0.7ºF) excluding probe error
BNC Inputs 1 for pH electrode
Calibration Check
Status of electrode condition and response time
status of the buffer solutions during calibration
Relative mV
Offset Range ±2000 mV
pH Calibration automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
Temperature Compensation Automatic or manual, -20.0 to 120°C (-4 to 248°F)
pH Electrode HI 1131P, glass body, refillable, BNC + pin connectors, 1 m cable (included)
Temperature Probe HI 7662-T with 1 m (3.3′) cable (included)
Input Impedance 1012 Ohm
Log-On-Demand 50 samples
Automatic Logging
1000 samples
PC Connection RS232 serial port, opto-isolated
Printer
built-in dot matrix printer, with 44 mm plain paper
Power Supply 12 Vdc adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 280 x 203 x 84 mm (11.0 x 8.0 x 3.3″)
Weight 1.9 kg (4.2 lbs.)
Accessories
Electrodes
HI 1043P Combination pH Electrode, Refillable w/ Double Junction
BNC Connection + pin
HI 1053P Combination pH Electrode, Refillable w/ Conical Tip
BNC + pin Connection
HI 1083P Combination pH Electrode w/ Micro Bulb
BNC + pin Connection
HI 1131P Refillable, Combination pH Electrode for the Laboratory and Beer Testing
BNC + pin Connection
HI 7662-T Stainless Steel Temperature Probe
Solutions
HI 5004L pH 4.01 buffer solution
HI 5007L pH 7.01 buffer solution
HI 5010L pH 10.01 buffer solution
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
HI 7071 Electrolyte Solution, 3.5M KCl + AgCl
4 x 30 mL bottles
HI 7072 Electrolyte Solution, 1M KNO³
4 x 30 mL bottles
HI 7082 Electrolyte Solution, 3.5M KCl
4 x 30 mL bottle
Accessories
HI 710032 Paper for Built-in Printers
HI 710033 Ink Cartridge for Built-in Printers
HI 76405 Electrode Holder with Steel Base
HI 92000 Windows® Compatible Software
HI 920010 Cable for PC Connection, 9 to 9-pin
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit
E-mail : info@highents.com