อุปกรณ์วัด pH (pH meter professional wine with Calibration Check ™ and specific electrode HI 1048P)
HI 2222-02
pH meter professional wine with Calibration Check ™ and specific electrode HI 1048P
What does it mean to use a pH electrode dirty? Most of the pH measurements during the winemaking process are performed on the must and the wine during maturing. A pH electrode gets dirty quickly during this type of measures, because of the numerous chemical and biological agents, also invisible to the naked eye, which adhere to the membrane of sensitive glass and the junction. These deposits cause many problems during the measurement of pH and subsequently, if the electrode is not properly cleaned.
A dirty pH electrode can give wrong measurements up to 0.5 pH units, even immediately after a calibration. A normal pH does not warn the user when the electrode is dirty. A typical example is when an electrode is immersed, immediately after the calibration, in a buffer solution at pH 7 and the reading is lower than expected (pH 6.8 or 6.9 instead of 7.0).
HI 2222 has a unique technology in its Typically, that uses a complex system of control of the electrode with 2 indicators to 10 levels, to detect when an electrode is dirty and alert the operator during calibration. It is of fundamental importance clean accurately a pH electrode before its use, using cleaning solutions specifications, in order to remove all deposits from the glass membrane sensitive and from the junction. HI 70635 (removal of deposits of wine) and HI 70636 (removal of pigments of wine) are cleaning solutions specifically designed for the wine industry, designed to remove all debris from your electrodes and measures to ensure more accurate and a long service life ‘ pH electrode. HANNA Instruments is the only manufacturer that offers this type of cleaning solutions specific to the wine.
Specifications HI 2222-02
Parameter
PH scale -2.00 To 16.00 pH
PH resolution 0.01 pH
Accuracy pH (at 20 ° C) ± 0.01 pH
MV ± 699.9 mV, ± 2000 mV
MV resolution 0.1 mV (± 699.9 mV), 1 mV (± 2000 mV)
Accuracy mV (at 20 ° C) ± 0.2 mV (± 699.9 mV) ± 1 mV (± 2000 mV)
Scale temperature -20.0 To 120.0 ° C
Temperature resolution 0.1 ° C
Accuracy at 20 ° C temperature ± 0.2 ° C
Calibration Check ™ control of the condition, the response time of the electrode and control buffer solutions during calibration
PH calibration automatic, 1 or 2 points on 7 memorized buffers (pH 1.68, 3.00, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature Compensation manual or automatic from -20.0 to 120.0 ° C
PH electrode HI 1048P glass, PTFE collar, double junction, refillable, BNC connector + pin (included)
Temperature Probe HI 7662 stainless steel (included)
Interfaces USB with HI 92000 software (optional)
Automatic storage 100 measurements
Input Impedance 10 12 Ohm
Supply 12 Vdc adapter (included)
Terms of use from 0 to 50 ° C; RH max 95%
Dimensions and weight 235 x 222 x 109 mm / 1.3 kg
Accessories HI 2222-02
HI 1048P PH electrode for wine and must, with sleeve diaphragm, PTFE collar, 1 m cable, BNC connectors and banana, for HI 222
HI 50003-01 Solution pH 3.00, 10 sachets of 20 ml, ± 0.01 pH, with certificate of analysis
HI 50003-02 Solution pH 3.00, 25 sachets of 20 ml, ± 0.01 pH, with certificate of analysis
HI 50007-01 Solution pH 7.01, 10 sachets of 20 ml, ± 0.01 pH, with certificate of analysis
HI 50007-02 Solution pH 7.01, 25 sachets of 20 ml, ± 0.01 pH, with certificate of analysis
HI 5003 Solution pH 3.00, 500 mL, ± 0.01 pH, with certificate of analysis
HI 5007 Solution pH 7.01, 500 mL, ± 0.01 pH, with certificate of analysis
HI 700635P Cleaning Solution for wine industry (tartaric acid), 25 sachets of 20 ml
HI 700636P Cleaning Solution for wine industry (wine stains), 25 sachets of 20 ml
HI 70300L Electrode storage solution, 500 mL
HI 70635M Cleaning Solution for wine industry (tartaric acid), 230 mL
HI 70636M Cleaning Solution for wine industry (wine stains), 230 mL
HI 7082 3.5 M KCl electrolyte solution (4×30 ml)
HI 76404N Stand holders for tools like HI 4211
HI 7662 Thermistor temperature probe
HI 92000 Windows ® compatible software for PC connection
HI 920010 RS232 cable for connection to PC for benchtop