Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Multiparameter Meter>>Multiparameter Portable Meter>>อุปกรณ์วัด Multiparameter (Multiparameter Meter pH/ORP/ISE, EC/TDS/Resistivity/Salinity/Seawater Spe
  • header_20130408111928.jpg

    อุปกรณ์วัด Multiparameter (Multiparameter Meter pH/ORP/ISE, EC/TDS/Resistivity/Salinity/Seawater Specific Gravity, Turbidity, DO, Temperature and Atmospheric Pressure)

    HI 9829

    Multiparameter Meter pH/ORP/ISE, EC/TDS/Resistivity/Salinity/Seawater Specific Gravity, Turbidity, DO, Temperature and Atmospheric Pressure

    Rugged, waterproof and easy to use, the HI 9829 is the ideal meters for field measurements of lakes, rivers and seas. Both meters display 1 to 12 parameters simultaneously from up to 15 user selectable parameters.

    Combined with one of the HI 76×9829 series probes, the HI 9829 can measure water quality parameters such as pH, ORP, conductivity, turbidity, temperature, ions ions ammonium, nitrate, chloride (NH4+, NO3-—N or Cl-), dissolved oxygen concentration, resistivity, TDS, salinity, and seawater specific gravity. Atmospheric pressure is measured for DO compensation.

    This meter features a graphic, backlit LCD that scales digits to fit up to 12 parameters and allows full configuration of each parameter measured along with an on-screen graphing capability.

    HI 9829 incorporates comprehensive GLP features and the transferring of data via USB connection. The HI 98290’s HELP key displays context sensitive help. The alpha-numeric keypad offers a user friendly way to complete the input fields.

    The Perfect Monitoring Tool

    Water scientists and managers alike utilize data-collection programs as part of environmental monitoring. These programs are designed to reveal changes in water and the environment around it over time. Reliable, dependable measurements are required to monitor these changes and understand the contributions from seasonal fluctuations, weathering, as well as manmade pollution. The HI 7629829 or HI 7639829 intelligent autonomously logging probes can be left at the application site to autonomously log results without the aid of the HI 9829 or a PC. When it is time to retrieve the results the measurement data can be easily transferred to the meters or PC using HI 929829 software.

    Sensors

    Sensor replacement is quick and easy with screw type connectors and color coded sensors. The HI 9829 automatically recognizes sensor presence.

    The HI 7609829-2 galvanic DO sensor with its fast response time can be ready at a moment’s notice. This probe features a replaceable membrane cap for easy maintenance.

    The HI 7609829-3 4-electrode conductivity probe uses a polarographic measurement principle and ensures stable conductivity readings that are immune to polarization or surface coating. Absolute conductivity, temperature compensated conductivity, salinity, specific gravity and TDS determinations are possible with measurements from this sensor.

    The new HI 7609829-4 EC/turbidity sensor is field replaceable and offers readings from both parameters at the same time.

    All potentiometric sensors feature a double junction design and are gel filled to increase resistance to contamination. An ISE sensor can be used in place of the pH sensor and is automatically recognized. pH in mV readings are also displayed —ideal for troubleshooting.

    A Great Combination

    The use of HANNA’s microprocessor based multiparameter intelligent probes with HI 9829 meter will provide reliable data collection that can lead to an improved scientific understanding of the interconnections between natural, chemical and geological processes and man made pollution to effectively evaluate applications for waste-discharge permits, remediate contaminated sites and to protect or restore biological resources.

    The HI 76×9829 probes utilize field replaceable sensors with auto-recognition. The sensors are housed with the probe electronics in a rugged housing with a water-tight cable connection. The base probe model permits the measurement of conductivity, pH/ORP (or an ISE), and dissolved oxygen. Other models permit turbidity and logging.

    The probes are available with a choice of cable lengths such as 4 m and 10 m and 20 m (13, 33’) that utilize a DIN connection to interface with the meters. The probes are supplied with a maintenance kit in the carrying case versions. These new probes can be connected directly to a PC with the HI 96982910 USB adapter, and the HI 929829 PC software to communicate directly with the probes.

    Reliable temperature measurements are a critical parameter of aquatic system monitoring. Temperature and temperature changes due to water releases can affect the ability of water to hold oxygen as well as the ability of organisms to resist certain pollutants. The intelligent probes incorporate an accurate thermistor that changes predictably with temperature changes. Accurate temperature reading in degrees Celsius, Kelvin or Fahrenheit are displayed and utilized by other detectors for temperature correction.

    The pH or pH/ORP sensors incorporate the technology that has made HANNA so successful as a pH manufacturer. Reliable pH measurements are one of the most important indicators of water chemistry indicating the relative amount of free hydrogen and hydroxyl ions in the water. HANNA’s pH sensors utilize a resilient PEI body to protect them from solid particulates found water samples. Consistency and quality are the hallmarks of these sensors. Our differential measurement system further enhances the measurement reliability providing temperature corrected pH.

    A choice of 3 ion selective electrodes is available for constant  reporting of common surface water contaminants. Nitrate, ammonium and chloride are available. Each ISE is a combination electrode incorporating an extremely constant reference spiral; all potentionmetric probes feature a double junction and solid gelled reference design. By utilizing conductivity, the HI 9829 can convert ion activity measurements to concentration units.

    The HANNA 4-electrode conductivity probe using the polarographic measurement principal ensures stable conductivity readings. Electrolytic conductivity measures of the ability of water to conduct an electrical current. It is highly dependent on the amount of dissolved solids (such as salt) in the water. Absolute conductivity, temperature corrected conductivity, salinity, specific gravity and water hardness (TDS) determinations are possible with measurements from this sensor.

    The oxygen dissolved in lakes, rivers, and oceans is crucial for the organisms and creatures living in it. If dissolved oxygen concentrations drop below normal levels in water bodies, the water quality degrades and the organisms begin to die off. The galvanic sensor does not require long polarization times so is ready for measurement at a moment’s notice. Our sensor also utilizes a replaceable cap design for ease of maintenance and a safe non-toxic electrolyte. DO readings are compensated for the effects of temperature (using the probes built-in temperature sensor) and atmospheric pressure (using the HI 9829’s internal atmospheric pressure sensor).

    The new HANNA turbidity sensor is a replaceable design for instantaneous turbidity reading that conforms to ISO 7027 standards.  It provides measurements from 0.0 to 50.0 FNU;  and 50 to 1000 FNU. Turbidity is the amount of particulate matter that is suspended in water. Turbidity measures the scattering effect that suspended solids have on light: the higher the intensity of scattered light, the higher the turbidity. Material that causes water to be turbid include: clay, silt, finely divided organic and inorganic matter, soluble colored organic compounds, plankton and microscopic organisms.

    Probes with the logging function have a logging memory that allows storage of up to 140,000 individual samples or 12,000 complete sample data sets with date and time stamp thus permitting up to a 35 day deployment with all channels logging at 10 minute intervals. Logging probes work with either rechargeable or standard batteries

    The probe incorporates a temperature sensor for temperature compensation of all parameters.

    Monitoring and Tracking

    When data collection or monitoring requires tracking capabilities, two kinds of methods can be included with the data—timestamp and location.  The timestamp expresses the date and the time when the measurement was taken. The time and date (timestamp) are determined by the internal real time clock of the HI 9829. As for location of measurement, the HI 9829 offers the FastTracker™ Tag ID system using ID encoded TAGs mounted at the location sites. Users simply touch the TAG receiver to the mounted TAG to store data along with location ID.

    Fast Tracker™—Tag Identification System

    HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButton®s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.

    iButton® Tags are Easy to Install

    Install the optional TAGs near your sampling points for quick and easy iButton® readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

    *Google™ is a registered trademark of Google™, inc.  HANNA Instruments® has no affiliation with Google™.

    METER ONLY, CARTON BOX PACKAGING
    HI 9829-01    Meter only, charging adapter and instruction manual, 115VAC
    HI 9829-02    Meter only, charging adapter and instruction manual, 230VAC

    METER AND PROBE ONLY, NO SENSORS, CARRYING CASE PACKAGING
    HI 98291-01    HI 9829 and HI 7629829/4 logging probe for pH/pH+ORP/ISE, DO, EC, temperature, with 4 m (13.1’) cable, probe maintenance kit, charging adapter, instruction     manual and hard carrying case, 115VAC
    HI 98291-02     HI 9829 and HI 7629829/4 logging probe for pH/pH+ORP/ISE, DO, EC, temperature, with 4 m (13.1’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 230VAC
    HI 98292-01     HI 9829 and HI 7639829/4 logging probe for pH/pH+ORP/ISE, DO, EC+turbidity, temperature, with 4 m (13.1’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 115VAC
    HI 98292-02     HI 9829 and HI 7639829/4 logging probe for pH/pH+ORP/ISE, DO, EC+turbidity, temperature, with 4 m (13.1’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 230VAC
    HI 98293-01     HI 9829 and HI 7629829/10 logging probe for pH/pH+ORP/ISE, DO, EC, temperature, with 10 m (33’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 115VAC
    HI 98293-02     HI 9829 and HI 7629829/10 logging probe for pH/pH+ORP/ISE, DO, EC, temperature, with 10 m (33’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 230VAC
    HI 98294-01     HI 9829 and HI 7639829/10 logging probe for pH/pH+ORP/ISE, DO, EC+turbidity, temperature, with 10 m (33’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 115VAC
    HI 98294-02     HI 9829 and HI 7639829/10 logging probe for pH/pH+ORP/ISE, DO, EC+turbidity, temperature, with 10 m (33’) cable, probe maintenance kit, charging adapter, instruction manual and hard carrying case, 230VAC

    Specifications

    Range pH/mV of pH input 0.00 to 14.00 pH/±600.0 mV
    ORP mV ±2000.0 mV
    Ammonium-
    Nitrogen 0.02 to 200 ppm (as N)
    Chloride 0.6 to 200 ppm
    Nitrate-Nitrogen 0.62 to 200 ppm (as N)
    Conductivity 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
    TDS 0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)
    Resistivity 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
    Salinity 0.00 to 70.00 PSU
    Seawater σ 0 to 50.0 st, s0, s15
    Turbidity 0.0 to 99.9 FNU; 100 to 1000 FNU
    Dissolved Oxygen 0.0 to 500.0%; 0.00 to 50.00 ppm
    Atm. Pressure 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
    Temperature -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K
    Resolution pH/mV of pH input 0.01 pH / 0.1 mV
    ORP mV 0.1 mV
    Ammonium-
    Nitrogen 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
    Chloride 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
    Nitrate-Nitrogen 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
    Conductivity manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
    TDS manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt); autorange scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); autorange g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
    Resistivity dependent on resistivity reading
    Salinity 0.01 PSU
    Seawater σ 0.1 σt, σ0, σ15
    Turbidity 0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU
    Dissolved Oxygen 0.1%; 0.01 ppm
    Atm. Pressure 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
    Temperature 0.01°C; 0.01°F; 0.01K
    Accuracy @ 20°C pH/mV of pH input ±0.02 pH / ±0.5 mV
    ORP mV ±1.0 mV
    Ammonium-
    Nitrogen ±5% of reading or 2 ppm, whichever is greater
    Chloride ±5% of reading or 2 ppm, whichever is greater
    Nitrate-Nitrogen ±5% of reading or 2 ppm, whichever is greater
    Conductivity ±1% of reading or ±1 µS/cm, whichever is greater
    TDS ±1% of reading or ±1 mg/L, whichever is greater
    Salinity ±2% of reading or ±0.01 PSU, whichever is greater
    Seawater σ ±1 σt, σ0, σ15
    Turbidity ±0.3 FNU or ±2% of reading, whichever is greater
    Dissolved Oxygen 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm: ±1.5% of reading or 0.10 ppm, whichever is greater; 30.00 ppm to 50.00 ppm: ±3% of reading
    Atm. Pressure ±3 mm Hg within ±15°C from the temperature during calibration
    Temperature ±0.15°C; ±0.27°F; ±0.15K
    Temperature
    Compensation  automatic from -5 to 55°C (23 to 131°F)
    Logging Memory
    from Meter  44,000 records
    Logging Interval  1 second to 3 hours
    Computer Interface  USB (with HI 929829 software)
    FastTracker™ TAG ID  yes
    Waterproof Protection  IP67
    Environment  0 to 50°C (32 to 122°F); RH 100%
    Power Supply  1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4), USB, 12V power adapter
    Dimensions  221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
    Weight  750g (26.5 oz.)

    Accessories

    Solutions
    HI 9829-16  Turbidity Calibration Solution, 0 FNU, 230 mL
    HI 9829-17  Turbidity Calibration Solution, 20 FNU, 230 mL
    HI 9829-18  Turbidity Calibration Solution, 200 FNU, 230 mL
    Accessories
    HI 929829  PC Application Software
    HI 7698291  USB Cable, PC to Meter
    HI 76982910  USB cable, PC to Probe
    HI 710046  Lighter Cigarette Cable
    HI 7698290  Short Calibration Beaker
    HI 7698293  Long Calibration Beaker
    HI 7698294  Short Flow Cell
    HI 7698297  Long, Quick Release Flow Cell
    HI 7698295  Short Protective Shield
    HI 7698296  Long Protective Shield
    HI 920005  iButton® Tags
    HI 710140  Hard Carrying Case
    HI 710045  Power Supply Cable
    Reagents & Standards
    HI 9829-10/11  ISE Standards Kit for HI 7609829-10, 10 Sachets ea.
    HI 9829-10  10 ppm Standard Sachets for HI 7609829-10 Ammonium ISE
    HI 9829-11  100 ppm Standard Sachet for HI 7609829-10 Ammonium ISE
    HI 9829-12/13  ISE Standards kit for HI 7609829-11 Chloride ISE
    HI 9829-12  10 ppm Standard Sachets for HI 7609829-11 Chloride ISE
    HI 9829-13  100 ppm Standard Sachet for HI 7609829-11 Chloride ISE
    HI 9829-14/15  ISE Standards for 7609829-12 Nitrate ISE
    HI 9829-14  10 ppm Standard Sachets for HI 7609829-12 Nitrate ISE
    HI 9829-15  100 ppm Standard Sachets for HI 7609829-12 Nitrate ISE
    Probes
    HI 7609829-0  pH Sensor
    HI 7609829-1  pH/ORP Sensor
    HI 7609829-2  Dissolved Oxygen Sensor
    HI 7609829-3  Conductivity Sensor
    HI 7609829-4  Conductivity/Turbidity Sensor
    HI 7609829-10  Ammonium ISE
    HI 7609829-11  Chloride ISE
    HI 7609829-12  Nitrate ISE
    Quick Calibration Solutions
    HI 9828-25  Quick Calibration Solution, 500 mL
    HI 9828-27  Quick Calibration Solution, 1 Gallon
    pH Calibration Solutions
    HI 7004L  4.01 pH Buffer Solution
    1 x 500 mL bottle
    HI 7007L  7.01 pH Buffer Solution
    1 x 500 mL bottle
    HI 7010L  10.01 pH Buffer Solution
    1 x 500 mL bottle
    ORP Calibration Solutions
    HI 7021L  ORP Test Solution at (240 mV @ 25°C/77°F)
    1 x 500 mL bottle
    HI 7022L  ORP Test Solution at 470 mV @ 25°C/77°F)
    1 x 500 mL bottle
    Dissolved Oxygen Solutions
    HI 7040L  Zero Oxygen Solution
    HI 7042S  Electrolyte Solution for Galvanic Probes
    Conductivity Calibration Solutions
    HI 7030L  12880 µS/cm EC Solution, 500 mL Bottle
    HI 7031L  1413 µS/cm EC Solution, 500 mL Bottle
    HI 7033L  84 µS/cm EC Solution, 500 mL Bottle
    HI 7034L  80000 µS/cm EC Solution, 500 mL Bottle
    HI 7035L  111800 µS/cm EC Solution, 500 mL Bottle
    HI 7039L  5000 µS/cm EC Solution, 500 mL Bottle
    Cleaning and Maintenance Solutions
    HI 70300L  Electrode Storage Solution
    1 x 500 mL bottle
    HI 7061L  General Purpose Cleaning Solution
    1 x 500 mL bottle

  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<