อุปกรณ์วัด Control System (pH Digital Controller with Matching Pin and PID Control)
pH 502
pH Digital Controller with Matching Pin and PID Control
The pH 502 series of controllers offer many features to increase the level of control available in your plant. These instruments can be configured to utilize P, PI, PID controlling. With this feature, the pH 502 takes the place of three instruments that only allow one configuration each. The pH 502 line includes models that incorporate control through analog output to drive any compatible device, such as an electrovalve or pump. Models equipped with a solid state relay are also available to ensure maximum life of the switching device. Each model has a differential input for a grounding bar to extend electrode life. Several models come with an RS485 port, as well as analog recorder output.
Fail Safe Alarm System protects against power interruption or line failure. 1, 2 or 3 point automatic calibration and manual or Automatic Temperature Compensation complete the features of this controller.
Choose your configuration
pH 502421-1 dual setpoint with SSR relay, on/off and PID controls, analog output, 115V
pH 502421-2 dual setpoint with SSR relay, on/off and PID controls, analog output, 230V and PID controls, RS485 output, 230V
Specifications
Range pH 0.00 to 14.00 pH
Temperature -9.9 to 120°C
Resolution pH 0.01 pH
Temperature 0.1°C
Accuracy @ 20°C pH ±0.02 pH
Temperature ±0.5°C
Input Impedance 1012 Ohm
pH Calibration automatic, one, two or three point, at pH 4.01, 7.01, 10.01
Temperature
Compensation automatic (with Pt100 probe) or manual from -9.9 to 120°C
Outputs digital: RS485 bi-directional opto-isolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC
Set Point Relay 1 or 2 contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load) or 1 or 2 Solid State Relay (SSR), 1A, 250 VAC (resistive and inductive load), fuse protected (2A, 250V fast fuse)
Alarm Relay one contact output SPDT, 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (5A, 250V fuse)
Power Supply 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Power Consumption 15 VA
Over Current
Protection 400 mA 250V fast fuse
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions panel cutout: 140 x 140 mm, instrument: 144 x 144 x 170 mm
Weight 1.6 kg (3.5 lb.)
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit
E-mail : info@highents.com