    อุปกรณ์วัด Control System (pH Analog Controller with Self-Diagnostic Test)

    HI 8710

    pH Analog Controller with Self-Diagnostic Test

    HI 8710 is a panel mounted pH controller with self-diagnostic test capabilities. Users can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous on or OFF and the over dosage control by setting the overtime dosage knob.

    When used in conjunction with the HI 8720 ORP controller, the ODCD* function will ensure that the ORP dosage will start only when the pH level is correct.

    “Overtime dosage” function with selection knob and jumper for disable on the rear panel. If the dosing relay remains continuously activated for more than selected dosing time the alarm relay is activated, the alarm LED is blinking and the dosing relay is deactivated.

    Specifications

    Range  0.00 to 14.00 pH
    Resolution  0.01 pH
    Accuracy
    @ 20 °C  ±0.02 pH (0 to 100 °C)
    ±0.05 pH (-20 to 0 °C)
    ±0.5% (input from transmitter)
    Input  high impedance 1012 Ohm; reference and matching pin inputs are available; 4-20 mA
    Power Output  ±5 Vcc; 150 mA max load for amplified electrodes
    Calibration  offset: ±2 pH with OFFSET trimmer
    slope: 80 to 110% with SLOPE trimmer
    Temperature
    Compensation  fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F)
    Recorder Output  0-20 mA or 4-20 mA (isolated)
    Setpoint Relay  1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
    Setpoint Range  0.00 to 14.00 pH
    Alarm Relay  1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
    Alarm Range  0.2 to 3.00 pH
    Consent Relay  1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
    Dosing Control  OFF/AUTO/ON with selection switch
    Over Dosing Control  adjustable, from 5 min to 60 min with knob or disable by wire strap – on rear panel
    Backlight  continuous on
    Power Supply  115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
    Enclosure  flame retardant ABS body and front panel; transparent splash-proof front cover
    Environment  -10 to 50°C (14 to 122°F); RH max 95% non-condensing
    Panel Cutout  141 x 69 mm (5.6 x 2.7″)
    Weight  1 kg (2.2 lb.)

    Accessories

    Solutions
    HI 7004/1L  4.01 pH Buffer Solution
    1 x 1 L bottle
    HI 7007/1L  7.01 pH Buffer Solution
    1 x 1 L bottle
    HI 7010/1L  10.01 pH Buffer Solution
    1 x 1 L bottle
    Accessories
    HI 8427  pH and mV Precision Simulator
    HI 931001  pH and mV Precision Simulator

  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<