อุปกรณ์วัด Conductivity/TDS (Bench-Top Multi-Range Conductivity Meter with ATC and Analog Output )
HI 23151
Bench-Top Multi-Range Conductivity Meter with ATC and Analog Output
The HI 23151 Bench-Top Multi-Range Conductivity Meter is a multi-range meter with built-in automatic temperature compensation for Conductivity measurements. The HI 23151 replaces EC 215R and features a large, easy to read LCD, solution holders and an attractive redesigned case.
The HI 23151 utilizes a four ring potentiometric probe with platinum sensor that offers greater versatility and accuracy over typical amperometric designs. A potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method, it is possible to measure very low to high conductivity levels (up to 200 mS/cm) without changing probes.
The temperature coefficient correction is adjustable from 0 and 2.5%/°C.
FEATURES/BENEFITS:
* Four ring potentiometric platinum probe
* Four measurement ranges
* ±1% F.s. accuracy
* Manual calibration
* Analog output
* Automatic Temperature Compensation
* Large LCD
* Built-in Solution Holders
FEATURES IN DEPTH:
Four ring probe – This allows for 1 probe to measure 4 ranges with no polarization effect. It provides an increased accuracy (1% F.S.) over amperometric style meters.
Analog output – Allows a recording device to be connected to the meter.
Manual calibration – This simple to use feature allows the HI2315 Bench-Top Conductivity Meter to be calibrated to any value within the measurement ranges (0.0 to 199.9 µs/cm; 0 to 1999 µs/cm; 0.00 to 19.99 ms/cm; 0.0 to 199.9 ms/cm) It is also less expensive than models with auto-calibration.
Manual adjustable temperature correction coefficient (ß = Beta) – This simple to use feature allows for different temperature correction coefficients to be used based on the sample being tested. It is adjustable from 0-2.5%/°C.
Automatic Temperature Compensation – This helps provide the HI 23151 with higher accuracy since conductivity is very sensitive to temperature variations.
Large LCD – The new, larger LCD is bright and easy to read.
Built-in Solution Holders – The HI 23151 has solution holders built into the casing. This convenient feature saves space and prevents solutions from tipping over.
Recessed Connector Bay – Protects connectors from liquids.
PRIMARY APPLICATIONS:
* Municipal drinking water, environmental studies
* Printing industry – Fountain solution maintenance
* Water Treatment – Boiler/Cooling Tower water quality
* Agriculture – Fertilizer concentration
* Food processing – salt levels in food. (i.e. making pickles)
* Education – Teach students about EC
Electrodes
HI 76303 Platinum 4-Ring Potentiometric Conductivity Probe with internal temperature sensor, DIN connector and 1 m (3.3′) cable
Solutions
HI 5030-12 12880 µS/cm EC Solution (120ml)
HI 5031-12 1413 µS/cm EC Solution (120ml)
HI 5033-12 84 µS/cm EC Solution (120ml)
HI 5034-12 80000 µS/cm EC Solution (120ml)
HI 7035L 111800 µS/cm EC Solution (500ml)
HI 7039L 5000 µS/cm EC Solution (500ml)
HI 7061L Cleaning Solution (500ml)
Accessories
HI76404 Electrode Holder
HI 710005 Power Adapter, 115 Vac to 12 VDC, US Plug
HI 710006 Power Adapter, 230 Vac to 12 VDC, European Plug
HI 740036P 100 mL Plastic Beaker
Order Information:
HI 23151-01 (115V) and HI 23151-02 (230V) are supplied with HI 76303 Platinum 4-Ring Potentiometric Conductivity Probe, 12 VDC adapter and instruction manual.
- Specifications
Range | 0.0 to 199.9 µs/cm; 0 to 1999 µs/cm; 0.00 to 19.99 ms/cm; 0.0 to 199.9 mS/cm | |
Resolution | 0.1 µs/cm; 1 µs/cm; 0.01 mS/cm; 0.1 mS/cm | |
Accuracy (@20°C/68°F) | ±1% F.s. (excluding probe error) | |
Calibration | Manual, one point | |
Temperature Compensation | Automatic, 0 to 50°C (32 to 122°F)with ß adjustable from 0 to 2.5%/°C | |
Analog Output | 0 to 5 Vcc not isolated on each range | |
Probe | HI 76303, platinum four ring conductivity probe with internal temperature sensor, Din connector and 1 m (3.3’) cable (included) | |
Power Supply | 12 VDC adapter (included) | |
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit
E-mail : info@highents.com