Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Checker>>Checker HC Handheld Colorimeter>>อุปกรณ์วัดแอมโมเนีย (Checker®HC Handheld Colorimeter – Ammonia High Range)
  • header_20130407112628.jpg

    อุปกรณ์วัดแอมโมเนีย (Checker®HC Handheld Colorimeter – Ammonia High Range)

    HI 733

    Checker®HC Handheld Colorimeter – Ammonia High Range

    The HI 733 Checker®HC is a simple, accurate, and cost effective way to measure high ranges of ammonia in fresh water.  Designed as a more accurate alternative to chemical test kits, the HI 733 provides quick, accurate results in four easy steps.


    1.) Step One – Add 1ml of sample and 9ml of reagent “B” to the included cuvette
    2.) Step Two – Insert sample into the Checker and zero it out
    3.) Step Three – Remove sample and add reagent “A”
    4.) Step Four – Reinsert sample and click the button to measure your results or…
    – Press and hold the button for 3 seconds for a time reaction reading

    The HI 733 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. 

    FEATURES/BENEFITS: 
    * Small palm-sized design
    * Accurate from ±1.0ppm ±5% of reading
    * Dedicated to a single parameter
    * Uses a single AAA battery
    * Auto Power Off after 10 minutes in inactivity
    * Built-in timer for timed reaction readings

    PRIMARY APPLICATIONS: 
    * Water Quality
    * Education
    * Wastewater
    * Environmental

     

     

     

    Order Information:
    The HI 733 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (1bottle of HI 733A-0 and 1 bottle of HI 733B-0), 1 x1.5V AAA battery, and an instruction manual.

     

     Specifications

    Range   0.0 to 99.9 ppm as NH4+
    Resolution   0.1 ppm
    Accuracy (@20°C/68°F)   ±1.0ppm ±5% of reading
    Measurement Method   Colorimetric
    Light Source   Photodiode @470 nm
    Light Detector   Silicon photocell
    Method   Adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
    Power Supply   Battery – 1 x 1.5V AAA
    Power Auto Off   After 10 min. of inactivity
    Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
    Weight   64 g (2.25 oz.)
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<