อุปกรณ์วัดฟอสเฟต (Checker®HC Handheld Colorimeter – Phosphate Low Range)
HI 713
Checker®HC Handheld Colorimeter – Phosphate Low Range
- Easier to use and more accurate than chemical test kits
Ascorbic acid method
±0.04 ppm ±4% of reading accuracy
Large, easy to read digits
Auto shut off
- Dedicated to a single parameter
Designed to work with HANNA’s reagents
Uses 10 mL glass cuvettes
- Small size, big convenience
Weighing a mere 64 g (2.25 oz.), the Checker®HC easily
fits into the palm of your hand or pocket
Use for quick and accurate on the spot analysis
Single button operation: zero and measure
Operated by a single AAA battery
- Ideal for:
Aquaculture, natural, waste, drinking waters and agriculture
Orthophosphates are found in natural and wastewaters. They are commonly added to drinking water as a corrosion inhibitor. The instantaneous analysis of orthophosphate by colorimetric determination provides rapid results using a standard analysis technique.
The HANNA HI 713 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give only a few resolution points while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 713 Checker®HC is accurate and affordable.
The HI 713 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and ±0.04 ppm (mg/L) ±4% of reading accuracy. The HI 713 Checker®HC uses an adaptation of Standard Method 4500-P E, Ascorbic Acid method.
The HI 713 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagents. Last, place the vial into the Checker®HC, press the button and read the results. It’s that easy.
Order Information:
HI 713 Checker®HC is supplied with sample cuvettes with caps (2), powder reagents for phosphate (6), battery and instructions.
Specifications
Range | 0.00 to 2.50 ppm (mg/L) | |
Resolution | 0.01 ppm (mg/L) | |
Accuracy @ 25°C | ±0.04 ppm (mg/L) ±4% of reading | |
Light Source | LED @ 525 nm | |
Light Detector | silicon photocell | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Battery Type | (1) 1.5V AAA | |
Auto-off | after two minutes of non-use and ten seconds after reading | |
Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
Weight | 64 g (2.25 oz.) | |
Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method |
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit
E-mail : info@highents.com