อุปกรณ์การไทเทรต
HI 902C
Automatic Titration System
Intuitive user interface
USB port allows for the transfer of methods and reports to a PC or another titrator via USB flash drive
Field upgradeable software
RS232 port allows direct connection to an analytical laboratory balance
Multi language support
Four working modes; potentiometric titrator, pH meter, mV meter, and ISE meter
Potentiometric titrator
Linked titration methods allow two methods to run in sequence
Acid/base, non-aqueous, ORP, complexation, back, precipitation titrations and titre determination can be performed
Supports up to 100 titration methods (standard and user defined)
Supplied standard methods pack or create your own
Titration graph can be displayed on-screen and saved as a bitmap
Choice of endpoint detection: equivalence point (1st or 2nd derivative) or fixed pH/mV value
Reminders for titrant age and standardization expiration
Multiple end-point titrations with multiple molecular weights and reaction ratios
Two sensor inputs with the addition of a second analog board
Supports two burette dosing pumps with the ability to perform back titrations
Clip-Lock exchangeable burette system enables users to exchange burettes in a matter of seconds
25 mL precision ground glass syringe with PTFE plunger
40,000 step screw drive, piston dosing pump
3-way motor driven valve
PTFE burette tubing with polyurethane tube jacketing
pH meter
Full featured research grade pH meter
Automatic Temperature Compensation (ATC)
Up to five calibration points with automatic recognition of standard buffers
Up to five custom buffers can be used for calibration
mV (ORP) meter
Relative mV calibration
ISE meter
Numerous concentration units including: mol/L, mmol/L, mg/L, mg/mL, ug/L, %, ppt, ppm, g/L, and user defined
Up to 5 calibration points with 5 custom standards
Powerful Customization, Accurate Analysis
The HI 902C is an automatic titrator that complements our wide range of products dedicated to quick and accurate laboratory analysis. HI 902C can perform acid/base, potentiometric, ORP, complexometric, precipitation, back titrations and titre determinations.
The HI 902C dispenses the titrant, detects the endpoint and performs all necessary calculations automatically.
This versatile titrator supports up to 100 methods, standard or user defined. When powered on, the instrument initiates an internal diagnostics check and then readies itself for the first titration of the day. A large color LCD screen clearly shows the chosen method and related information. A real-time titration curve can be shown on the display; this feature is useful when new methods are tested or when a procedure needs to be optimized. At the end of the titration, all data, including the graph, are automatically stored in memory and can be copied via the built-in USB drive or through direct connection with a PC.
This titrator is supplied with a pack of standard methods or you can create your own. Methods (standard and user) can be upgraded, stored or deleted by connecting the titrator to a PC with HANNA software or USB flash drive. Software updates can also be performed using a USB flash drive.
Users can connect pH, ORP or ISE electrodes to the HI 902C, as well as create a complete workstation with a PC, monitor, keyboard and printer.
The HI 902C complies with GLP specifications. All GLP information from each sample can be stored, including ID number, date and time of analysis, electrode ID code, and last calibration date.
Clip-Lock™ Exchangeable Burette System
With Clip-Lock™, it only takes a few seconds to exchange the reagent burettes to perform a different titration.
The Clip-Lock™ exchangeable burette system prevents cross contamination while reducing loss of time and reagents. Burettes simply slide out for quick exchanges and detaching the aspiration and dispensing tubes from the titrant bottles is easy.
Interrupting an important cycle of analysis due to a malfunctioning burette is a thing of the past. With the HANNA Clip-Lock™ system you can simply substitute the burette and complete all your tests with the same titrant!
Having several prepared burettes on hand will make the HANNA HI 902C one of the fastest and most versatile titration systems on the market.
Order Information:
HI 902C1-01 (115V) titrator with one analog board HI 902C1-02 (230V) titrator with one analog board HI 902C2-01 (115V) titrator with two analog boards HI 902C2-02 (230V) titrator with two analog boards All models include stirrer with stand, 25 mL glass burette, dosing pump drive, temperature sensor, USB cable, 256 Mb USB flash drive and PC software.
Specifications
Range mV -2000.0 to 2000.0 mV
pH -2.000 to 20.000 pH
ISE 1 x 10-6 to 9.99 x 1010
Temperature -5.0 to 105.0°C/23 to 221°F/268.2 to 378.2 K
Resolution mV 0.1 mV
pH 0.1/0.01/0.001 pH
ISE 1, 0.1, 0.01
Temperature 0.1°C/0.1°F/0.1K
Accuracy
(@25ºC/77ºF) mV ±0.1 mV
pH ±0.001 pH
ISE ±0.5% monovalent; ±1% divalent
Temperature ±0.1°C/±0.2°F/±0.1K (excluding probe error)
Burette Sizes 5, 10, and 25 mL
Burette Resolution 1/40000
Display Resolution 0.001 mL
Dosing Accuracy ±0.1% of full burette volume
Display 5.7” (320 x 240 pixel) backlit color LCD
Languages English, Portuguese, Spanish
Methods load up to 100 methods (standard and user-defined)
Burette Auto-Detection burette size is automatically recognized when inserted into the unit
Programmable Stirrer propeller type, 100-2500 RPM, automatically held within 10% of the set value, resolution 100 rpm
Flow Rate user-selectable from 0.1 mL/min to 2 x burette volumes/min
Temperature Compensation manual or automatic (ATC)
End-point Determination equivalence point (1st or 2nd derivative) or fixed pH/mV value
pH Calibration up to five point calibration, eight standard buffers and five custom buffers
mV Calibration single point offset
ISE Calibration up to five point calibration, seven standard solutions and five user defined standards
Potentiometric Titrations acid-base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric, back titrations and titre determination
Measurement Units user specified expression of concentration units to suit specific calculation requirements
Real Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode, mV-mode or ISE mode; pH/mV/concentration values versus time-datalogging results
Data Storage up to 100 titration and pH/mV/ISE reports
USB Host (Side) flash drive compatibility for transfers of methods and reports
Peripherals (Rear) connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232, interface for future expansion
GLP Conformity instrumentation data storage and printing capabilities
Operating Environment 10 to 40°C (50 to 104°F), up to 95% RH
Storage Environment -20 to 70°C (-4 to 158°F), up to 95% RH
Power “-01” models: 115VAC; “-02” models: 230VAC; 50/60 Hz
Dimensions 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
Weight approximately 10 kg (22 lbs.) with one pump and stirrer assembly
Accessories
Accessories
HI 900100 Dosing Pump
HI 900110 10 mL Burette
HI 900105 5 mL Burette
HI 900125 25 mL Burette
HI 900225 25mL Burette Syring
HI 900260 3-Way Valve
HI 900205 5 mL Burette Syringe
HI 900270 Aspiration Tube with Fitting
HI 900280 Dosing Tube
HI 900301 Overhead Stirrer Assembly
HI 900302 Propeller (Includes 3 Propellers)
HI 900310 Magnetic Stirrer
HI 900150 50 mL Burette
HI 900920 Temperature Probe
HI 900942 Burette Cap Removal Tool
HI 900941 Shorting Connector
HI 900930 RS232 Cable for PC Connection
HI 900942 Burette Cap Removal Tool
HI 900941 Shorting Connector
Requesting a Quotation and Ordering Products
131 Thailand Science Park. Innovation Cluster 1 Building,
Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. 02-191-3928 Fax 02-191-3929
For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit