Main Menu
สถิติเยี่ยมชม
  • หน้าแรก>>Products>>Filter & Extract>>Chromatography Filter>>อุปกรณ์กรอง Syringe Filter CHROMAFIL GF/RC
  • header_20130419194329.gif

    อุปกรณ์กรอง Syringe Filter CHROMAFIL GF/RC

    CHROMAFIL® GF/PET  
    Polyester syringe filters with glass fiber prefilters  
    Features  
    Combi syringe filters with a coarse glass fiber prefilter and a small-pore membrane as main filter  
    User benefits:

    For solutions with a high load of particulate matter: lower back pressure, easy filtration
    For high yields of filtrate: more mL of pure filtrate per filter
    The technology:
    The glass fiber membrane (1.0 µm) removes coarse particles, before they can block the fine main membrane. This results in a better filtration efficiency, especially for highly contaminated samples
      Housing: Solvent-resistant, ultra low bleed polypropylene
      Entry: Luer lock
      Exit: Luer
      Pore diameter: 1.0 / 0.20 µm or 1.0 / 0.45 µm
      Filter diameter: 25 mm
      Void volume: < 80 µL
      Packing unit: 100 filters / BIG-BOX with 400 filters
         

    Hydrophilic membrane
    For aqueous and organic – aqueous liquids, i.e. for polar and medium polar solutions
    Recommended for solutions with a high load of particulate matter or for highly viscous aqueous solutions
    Ordering information
    Color-coded regenerated cellulose – glass fiber combi filters

    Type Pore size Membrane Color code Standard pack BIG-BOX
      [µm] dia. [mm] top bottom Filters/pack REF Filters/pack REF
    GF/RC-20/25 1.0/0.20 25 blue blue 100 729050 400 729050.400
    GF/RC-45/25 1.0/0.45 25 black blue 100 729051 400 729051.400
     

    CHROMAFIL® filter membranes

     
    Chemical compatibility of filter materials  
    The following table lists the chemical compatibility of our CHROMAFIL® materials. The chemical compatibility depends on several parameters such as time, pressure, temperature and concentration. In most cases, CHROMAFIL® filters will have only short contact with a solvent.   In these cases they may be used despite of limited compatibility.
    For example, a PTFE filter with PP housing does not liberate any UV-detectable substances during filtration of 5 mL THF, although PP shows only limited resistance towards THF.

    Solvent Material
      MV CA RC PA PTFE H-PTFE PVDF PES PET GF PP
    Acetaldehyde o   o
    Acetic acid, 100 %
    Acetone
    Acetonitrile
    Ammonia, 25 % o o
    Benzene o   o
    n-Butanol o
    Cyclohexane o
    Dichloromethane
    Diethyl ether o o o
    Dimethylformamide o
    1,4-Dioxane o o
    Ethanol
    Ethyl acetate o
    Ethylene glycol o o
    Formic acid, 100 % o o
    Hydrochloric acid, 30 %
    Methanol
    Nitric acid, 65 % o o o   o
    Oxalic acid, 10 % aqueous  
    Petroleum ether
    ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • Requesting a Quotation and Ordering Products

    131 Thailand Science Park. Innovation Cluster 1 Building,

    Klong 1, Klong Luang, Pathumthani 12120 Thailand. 

    Tel.  02-191-3928 Fax 02-191-3929


    For more information please contact 081-847-6768 (Ms. Nareerat) IDLine: @alltestkit

    E-mail : info@highents.com

     

    >>Online Quotation Click here<<